The air-to-cloth (A/C) ratio is the actual gas flow through a baghouse divided by its total filter cloth area, expressed as the gas volume passing each square meter of cloth per minute (m/min). For the same gas flow it changes with the number and size of the filter bags, and it directly affects differential pressure and bag life.
Qₐ = QN × (273.15 + t) ÷ 273.15 × 101.325 ÷ (101.325 + Pₛ × 0.00981)Qₐ actual gas flow (m³/min), QN normal flow (Nm³/min), t operating temperature (°C), Pₛ static pressure (mmH₂O). QN is on a wet basis; atmospheric pressure is taken at sea level (101.325 kPa)A = π × D × L × NA cloth area (m²), D bag diameter (m), L bag length (m), N number of bagsv = Qₐ ÷ Av A/C ratio (m/min). For the net A/C ratio, use the area remaining after offline compartments are subtracted
Unit conversion: 1 m/min = 60 m/h = 3.281 ft/min. US references usually express the A/C ratio in ft/min, which is the same as acfm/ft².
Worked Example
Step
Calculation
Result
Actual gas flow
50,000 ÷ 60 × 443.15/273.15 × 101.325/99.854
1,371.9 m³/min
Cloth area
π × 0.16 × 6 × 600
1,809.6 m²
A/C ratio
1,371.9 ÷ 1,809.6
0.76 m/min (2.49 ft/min)
Net A/C ratio (1 of 6 compartments offline)
1,371.9 ÷ (1,809.6 × 5/6)
0.91 m/min
An incinerator baghouse treats 50,000 Nm³/h of flue gas at 170°C and −150 mmH₂O static pressure using 600 bags of Ø160 × 6,000 mm in six compartments. These are the calculator's default values.
What Does the Calculated A/C Ratio Tell You?
A higher A/C ratio pushes more gas through the same cloth area. Differential pressure rises, dust is driven deeper into the media, and cleaning frequency and bag wear tend to increase. The right range depends on dust properties, inlet loading, cleaning method and filter media.
Typical values by dust type are listed in Air-to-Cloth Ratios by Dust Type. They are general design values published by the U.S. EPA; an actual design should also consider particle size and dust loading.
In tall bags and high-inlet hoppers, also check can velocity (the upward gas velocity between bags), because a high value keeps dislodged dust from falling into the hopper.
Frequently Asked Questions
Are air-to-cloth ratio, gas-to-cloth ratio and filtration velocity the same thing?
Yes. Air-to-cloth ratio, gas-to-cloth ratio, filtration velocity and face velocity all describe the same value. It is expressed in m/min or (m³/min)/m², and US references usually use ft/min.
Can I calculate the A/C ratio directly from Nm³/h?
No. Dividing normal flow by cloth area understates the ratio. The A/C ratio must be based on the gas volume actually flowing at operating temperature and pressure. This calculator converts normal flow to actual flow using the operating temperature and static pressure before dividing.
Should compartments that are offline for cleaning be included in the cloth area?
If compartments are taken offline for cleaning or maintenance, the net A/C ratio, based on the remaining compartments, is closer to the real load on the bags. Check both the gross and net A/C ratio during design.
How can I lower the A/C ratio?
Increase the cloth area with more or longer bags, or reduce the gas flow or temperature. If the housing cannot take more cloth area, consider membrane filter bags, which keep differential pressure lower and more stable at the same A/C ratio.
U.S. EPA, Air Pollution Control Cost Manual, Section 6, Chapter 1, “Baghouses and Filters” — definition of gas-to-cloth ratio and net vs. gross cloth area Source
Your results or checked items are added to the inquiry note automatically. Add your company and email, and our engineer will reply with a filter proposal.
Data collected: company name and email (plus any contact details you add) · Purpose: to review and respond to your inquiry · Retention: 5 years as an inquiry record, then deleted
✓
Thank you. We have received your request.
Head Office
Micro-one Co., Ltd. (head office and factory)
368 Yeongok-gil, Ipjang-myeon, Seobuk-gu, Cheonan-si, Chungcheongnam-do 31026, Republic of Korea Tel: +82-41-587-6911Fax: +82-41-587-6922Email: info@micro-one.kr
Dangjin Plant 2
1307 Tongjeong-ri, Seongmun-myeon, Dangjin-si, Chungcheongnam-do, Korea
Seoul Office
165 Gasan Digital 1-ro, Geumcheon-gu, Seoul (371-6, Gasan-dong)